After Filters for Cyclone Dust CollectorsThe Filters for Cyclones
Sternvent after filters capture the fine dust that is not separated from the air stream of a cyclone dust collector. Simple and efficient, the after filters allow return of filtered air to the building or to comply with EPA requirement when exhausting the air outdoors.
Sizes
Sternvent offers 3 sizes, 6 00-6,000 cfm, of after filters in two styles; 55 gallon drum & dust chamber. Available for indoor installation or outdoors, when ordered with weatherproof enclosure. Filters are available 11-1/2” 05 5” diameter in polyester felt or cotton sateen. Ceiling hung and floor-mounted units are available.
Principle of Operation
The dirty air stream enters the plenum horizontally; the filters hang from the plenum. The air and dust go down, inside of the filter bags. The dust is stored in the 11-1/2 diameter filters. The 5” diameter filters are tubes that allow the dust to be deposited in the airtight 55 gallon drum or chamber. Some models are available with a motorized shaker to loosen the dust particles from the filters, to restore suction. Filtration efficiency is typically 99.9%. (For production operations, additional filter media is suggested. For sticky or agglomerating dust, a pulse jet style dusty collector should be used instead of the after filter.)
11 1/2" Diameter After Filter - Open Style
*Dust stored in zipper bottom bags for indoor installation. Ceiling hung.
11 1/2" Diameter After Filter - Enclosed Style
*Dust stored in zipper bottom bags for outdoor installation. Enclosure is not suitable for ducting back to the building.
5" Diameter After Filter - Open & Enclosed Style
*Dust stored in sweep out chamber or 55 gallon drum for models with D suffix. Enclosed models are for outdoors and are suitable for ducting each to building.
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||